Scienco-Fast

FAST ® Sewage Systems

Complete Package Units
for New or Existing Vessels

Click to go to FAST PAGE

Click to go to the French version

SUMMARY

Fast MaritimeClick here to get a Marine FAST ® picture(58 K)

INTRODUCTIONTop

Each D-Series FAST ® System is completely assembled, wired and tested on its own foundation. The unique design provides the greatest possible flexibility in locating and installing the system aboard ship.

Where space and access permit, the D-Series System can be installed as a unit. Shipboard connections and installation labor are reduced to an absolute minimum.

The D-Series Media Tank and Machinery Module can be furnished on separate foundations to use available space to best advantage, and the Media Tank itself can be furnished in bolt-together sections. All D-Series Systems are factory assembled, wired and tested. Bolt-together units can be broken down and reassembled in place.

Fully certified FAST ® sewage treatment systems are available in capacities up to 175,000 GPD. They are the best marine treatment systems in the world.

FLOW DIAGRAM

D-SERIES UNIT SPECIFICATIONSTop

General

Package unit, assembled and wired on steel skid, tested at factory before shipment. Includes valves, machinery and controls necessary for automatic operation.

Certifications

USCG Type II for Inspected Vessels, IMCO, Canadian Great Lakes.

Classification Societies

American Bureau of Shipping, Canada Steamship Inspection, Bureau Veritas, Det Norske Veritas, Germanischer Lloyd, Lloyd Register, Nippon Kaigi Kyokai, Polski Rejestr Statkov, Registry of the USSR.

Wastewaters treated

Any combination of raw, unscreened, fresh or salt water domestic sewage from standard or vacuum toilets, personal washwater, laundry or galley.

Effluent qualityTop

Equal or better than any known marine standard worldwide. Test reports available on request.

Process

Fixed Activated Sludge Treatment (FAST ®), patented aerobic biological process employs fixed media as site for microbial growth.

Rated capacity

Refer to Table.

Load variations

Unit shall operate properly and meet regulatory requirements at any loading from zero to overload capacity, including surges at change of watch, changes in crew size and changes in salinity of flushing water.

Overload capacity

Up to 25 % as a percentage of rated capacity, the average load shall not exceed:

Duration (days)         

1

2

3

4

5

6

7 or more

Average load (%)

125

115

110

107

104

102

100

OperationTop

Sewage enters media tank above constant waterline. Microbes normally found in sewage attach to fixed media and use organic material in sewage as food. Use of fixed media permits formation of much larger microbial population than would otherwise be possible, providing consistent treatment despite surges and other variations in loading. Unit can be bypassed up to 3 weeks, then fully treat sewage as vessel enters controlled waters. No obnoxious odors.

Compressed air operates airlifts to aerate and circulate contents of tank. Turbulence throws foreign objects to side of tank. Compressed air can be valved to air scour and clean tank before draining.

Process is inherently self regulating. There are no adjustments and proper operation does not depend on skill of personnel. Unit will handle any object which can pass through a toilet. No pre treatment, maceration, or screening is required.
Click here to see the Engineering Manual of T.S. Patriot State

DisinfectionTop

USCG and IMCO certified units employ solid tablet chlorine feeders. Dosage is proportional to flow. Canadian Great Lakes certified units employ ultraviolet sterilization in lieu of chlorination.

Equipment


Basic unit
Single vertical cylindrical media tank. Single vertical cylindrical chlorine contact tank. Unit incorporates structural steel skid, tablet chlorinator, air pressure regulator, and orifice plate and gravity overboard connection.
Aeration blower (if required)
Roots rotary lobe blower, belt drive, belt guard, relief valve, discharge check valve, silencer, motor and motor starter in lieu of pressure regulator and orifice plate. Fully assembled on system.
Discharge pump (if required)
Close coupled centrifugal, isolation valves, float switch in contact tank for automatic operation, motor and motor starter. Fully assembled on system. Pump is 85-5-5-5 marine bronze with stainless steel shaft and hardware.
Duplex Discharge Pumps (if required)
Two identical pumps per above, isolation and discharge check valves, standby pump starts automatically when high level float switch in contact tank energized, each pump sized for 100 % duty, either pump can be selected as duty pump. Fully assembled on system.
U.V. Sterilizer Package (if required)
U.V. Sterilizer and chart recorder for remote mounting in lieu of chlorinator. Discharge pump(s) required.
Modular construction (if required)
Media tank shall be assembled on its own structural base.
The contact tank, chlorinator and machinery shall be assembled as a machinery module on a separate structural base for remote installation. This will permit installation of the system in locations where sufficient space is not available for installation as a unit.
Modular Media Tank (if required)
For installation in existing vessels where access to the intended machinery space is limited. The media tank shall be furnished in bolt-together sections. Each section shall pass through a clear opening of dimensions as listed on the Data Table.
Remote Alarm Panel (if required)
Visible and audible alarms for high level and blower off. Low U.V. alarm included with U.V. sterilizer package.

ConstructionTop

All welded ABS Grade A (ASTM A-36) steel with bolted tank top, full structural steel skid, lifting lugs. Minimum section thickness 1/4 in. (6 mm). Bulkheads reinforced to withstand USCG / IMCO test head. All penetrations and tank seams full welded both sides.

Corrosion Protection

Interior and exterior surfaces grit blasted to white metal (S.S.P.C. 5). Two coats polyamide epoxy tank lining to 12-14 mils DFT. Assembly hardware and threaded tank nozzles stainless steel.

Electrical Equipment


Voltages
208 / 230 / 460 / 575 VAC 3 , 60 Hz and 380 VAC 3 , 50 Hz standard.
Motors
Totally enclosed fan cooled, marine duty, Class F insulation.
Controls
Across the line starting, overload protection all 3 phases, marine duty, NEMA 4 / IP65 enclosure, terminal board for external connections, manual overrides.
Electric Service Required
Refer to table.
Explosion proof equipment
Per USCG Electrical Engineering Regulations 46 CFR part 111.80-5(C) for Class 1, Division 2, Group D hazardous locations.

PipingTop

Schedule 40 steel, schedule 80 PVC or CPVC as applicable. All water piping external. Valve types and materials suitable for intended purpose.

Consumables

Chlorine consumption for continuous operation estimated at:

Waste Water

   Kg per man per year  

Black Water, vacuum toilets

0.30

Black Water, standard toilets

1.7

Gray Water

2.7

Ultraviolet lamps to be replaced at 8,000 hour intervals, yearly for continuous operation.

Options Available

Non standard voltages, special electrical enclosures, tank insulation and heaters for low temperature operation, metric (DIN) flanges, special tank and machinery arrangements are available.

Specifications are subject to change without notice.

Technical DataTop

The crew size shown on Data Table are for treatment of black water only for persons working and living aboard. If other type of sewage are to be treated, add appropriate factors given below to obtain service factor. Multiply service factor by actual crew size to obtain equivalent black water crew size and use this figure to select a unit from the table.

Type of sewage

   Service factor  

Toilets and urinals

1.00

Showers and lavatories

0.27

Laundry

0.28

Galley sink and dishwasher    

0.17

Galley garbage disposal

0.91

Total all domestic sewage

2.63

For persons working but not living aboard, or living but not working aboard, count each of these as one-half person to obtain equivalent crew size.

CLICK HERE TO GET TO A TECHNICAL DRAWING

FAST ® D-SERIES DATA TABLES

Dimensions (cm)

Weights (kg)

Model  

L

W

H

Dry

Operating

D1

210

120

200

1600

3200

D2

230

140

200

1900

4100

D3

270

170

200

220

6100

D4

310

200

200

2700

8400

D5

350

230

200

2900

9300

D6

400

280

200

3400

12300

D7

400

280

290

3700

15400

D8

490

340

290

4300

22200

D9

580

400

290

5000

31800

Piping Connections (")

Model

Crew Size

Aeration
(m3/h)

Inlet

Outlet
Gravity

Outlet
Discharge
Pump

Vent

D1

30

39

4

2

1-1/2

3

D2

45

60

4

2

1-1/2

4

D3

67

87

6

2

1-1/2

5

D4

97

130

6

2

1-1/2

5

D5

120

160

6

2

1-1/2

6

D6

173

228

6

2

1-1/2

8

D7

260

233

8

3

2

8

D8

406

365

8

4

2

8

D9

584

527

8

4

2-1/2

10

Electric Service Required (kVA)

Discharge Pump Static Lift (m)

Model

Blower

Discharge
Pump

Minimum Access
required (cm)

Model

60 Hz
Power

50 Hz
Power

D1

2.1

1.9

81 x 140

All

9

8

D2

2.1

1.9

81 x 140

-

-

-

D3

2.1

1.9

91 x 160

-

-

-

D4

3.7

1.9

99 x 200

-

-

-

D5

3.7

1.9

110 x 230

-

-

-

D6

3.7

1.9

-

-

-

-

D7

5.7

2.3

-

-

-

-

D8

8.1

2.3

-

-

-

-

D9

10.5

4.9

-

-

-

-

NOTE: dimensions and weights may vary slightly from those given in table depending on equipment selection.

If duplex pumps are required, increase outlet piping connection size by one pipe size.

Exclusive Benefits of FAST ®

Information More information                                                               Top Top