Click here to get
a Marine FAST ® picture(58 K)
Each D-Series FAST ® System is completely assembled, wired and tested on its own foundation. The unique design provides the greatest possible flexibility in locating and installing the system aboard ship.
Where space and access permit, the D-Series System can be installed as a unit. Shipboard connections and installation labor are reduced to an absolute minimum.
The D-Series Media Tank and Machinery Module can be furnished on separate foundations to use available space to best advantage, and the Media Tank itself can be furnished in bolt-together sections. All D-Series Systems are factory assembled, wired and tested. Bolt-together units can be broken down and reassembled in place.
Fully certified FAST ® sewage treatment systems are available in capacities
up to 175,000 GPD. They are the best marine treatment systems in the
world.
| Duration (days) | 1 |
2 |
3 |
4 |
5 |
6 |
7 or more |
Average load (%) |
125 |
115 |
110 |
107 |
104 |
102 |
100 |
USCG and IMCO certified units employ solid tablet chlorine feeders. Dosage is proportional to flow. Canadian Great Lakes certified units employ ultraviolet sterilization in lieu of chlorination.
All welded ABS Grade A (ASTM A-36) steel with bolted tank top, full structural steel skid, lifting lugs. Minimum section thickness 1/4 in. (6 mm). Bulkheads reinforced to withstand USCG / IMCO test head. All penetrations and tank seams full welded both sides.
Interior and exterior surfaces grit blasted to white metal (S.S.P.C. 5). Two coats polyamide epoxy tank lining to 12-14 mils DFT. Assembly hardware and threaded tank nozzles stainless steel.
Schedule 40 steel, schedule 80 PVC or CPVC as applicable. All water piping external. Valve types and materials suitable for intended purpose.
Chlorine consumption for continuous operation estimated at:
Waste Water |
Kg per man per year |
Black Water, vacuum toilets |
0.30 |
Black Water, standard toilets |
1.7 |
Gray Water |
2.7 |
Ultraviolet lamps to be replaced at 8,000 hour intervals, yearly for continuous operation.
Non standard voltages, special electrical enclosures, tank insulation and heaters for low temperature operation, metric (DIN) flanges, special tank and machinery arrangements are available.
Specifications are subject to change without notice.
The crew size shown on Data Table are for treatment of black water only for persons working and living aboard. If other type of sewage are to be treated, add appropriate factors given below to obtain service factor. Multiply service factor by actual crew size to obtain equivalent black water crew size and use this figure to select a unit from the table.
| Type of sewage | Service factor |
| Toilets and urinals | 1.00 |
| Showers and lavatories | 0.27 |
| Laundry | 0.28 |
| Galley sink and dishwasher | 0.17 |
| Galley garbage disposal | 0.91 |
| Total all domestic sewage | 2.63 |
For persons working but not living aboard, or living but not working aboard, count each of these as one-half person to obtain equivalent crew size.
CLICK HERE TO GET TO A TECHNICAL DRAWING
|
Dimensions (cm) |
Weights (kg) |
|||
Model |
L |
W |
H |
Dry |
Operating |
D1 |
210 |
120 |
200 |
1600 |
3200 |
D2 |
230 |
140 |
200 |
1900 |
4100 |
D3 |
270 |
170 |
200 |
220 |
6100 |
D4 |
310 |
200 |
200 |
2700 |
8400 |
D5 |
350 |
230 |
200 |
2900 |
9300 |
D6 |
400 |
280 |
200 |
3400 |
12300 |
D7 |
400 |
280 |
290 |
3700 |
15400 |
D8 |
490 |
340 |
290 |
4300 |
22200 |
D9 |
580 |
400 |
290 |
5000 |
31800 |
|
|
|
Piping Connections (") |
|||
Model |
Crew Size |
Aeration |
Inlet |
Outlet |
Outlet |
Vent |
D1 |
30 |
39 |
4 |
2 |
1-1/2 |
3 |
D2 |
45 |
60 |
4 |
2 |
1-1/2 |
4 |
D3 |
67 |
87 |
6 |
2 |
1-1/2 |
5 |
D4 |
97 |
130 |
6 |
2 |
1-1/2 |
5 |
D5 |
120 |
160 |
6 |
2 |
1-1/2 |
6 |
D6 |
173 |
228 |
6 |
2 |
1-1/2 |
8 |
D7 |
260 |
233 |
8 |
3 |
2 |
8 |
D8 |
406 |
365 |
8 |
4 |
2 |
8 |
D9 |
584 |
527 |
8 |
4 |
2-1/2 |
10 |
|
Electric Service Required (kVA) |
Discharge Pump Static Lift (m) |
||||
Model |
Blower |
Discharge |
Minimum Access |
Model |
60 Hz |
50 Hz |
D1 |
2.1 |
1.9 |
81 x 140 |
All |
9 |
8 |
D2 |
2.1 |
1.9 |
81 x 140 |
- |
- |
- |
D3 |
2.1 |
1.9 |
91 x 160 |
- |
- |
- |
D4 |
3.7 |
1.9 |
99 x 200 |
- |
- |
- |
D5 |
3.7 |
1.9 |
110 x 230 |
- |
- |
- |
D6 |
3.7 |
1.9 |
- |
- |
- |
- |
D7 |
5.7 |
2.3 |
- |
- |
- |
- |
D8 |
8.1 |
2.3 |
- |
- |
- |
- |
D9 |
10.5 |
4.9 |
- |
- |
- |
- |
NOTE: dimensions and weights may vary slightly from those given in table depending on equipment selection.
If duplex pumps are required, increase outlet piping connection size by one pipe size.
Clogging is virtually impossible. There are no moving parts in contact with
sewage. The bacteria consume rags, paper, sanitary napkins, etc. Such things
as plastic bags remain in a portion of the tank where there is a good access
for easy removal (but removal should not be needed for several years). Cigarette
filter tips and other small objects are pumped out with the sludge.